Service difficulty report · Check Valve · Boeing 777224

Difficulty date
March 21, 2014
Submitted
March 24, 2014
Operation
Air carrier
Aircraft
N79011
Make and model
Boeing 777224
Aircraft serial
29859
Aircraft time
73,837 hours, 7,552 cycles
Part
Check Valve
Part number
CV020T3E3
Condition
Failed
Location
Bleed Air Sys
Stage of operation
CR
How discovered
O
Nature of condition
O
Precautionary procedure
A

As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.

What was found

NO WATER PRESS IN ALL LAVATORY’S & WATER FAUCETS. IAW MX & SYS CONTROL DUMP 150,000 FUEL & AIR RETURNED TO EWR. UPON TROUBLESHOOTING FOUND THE BLEED AIR CHECK VLV JAMMED CLOSED. R & R SAME, ALSO FOUND THE WATER SYS DRAIN HANDLE AT 2L PARTIALLY OPEN, REPOSITIONED SAME. WATER SYS NOW PRESSURIZES NORMALLY WITH NO FAULTS IAW AMM 38-42-09.