What was found
CORROSION IN AFT PIT BILGE AREA ON STRINGERS & FASTENERS DOUBLER CUT OUTS FROM FRAME 63 - FRAME 64. R & R STRINGER 41RT FROM FRAME 58 - FRAME 64 IAW SRM 51-42-11, PG 7 E.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
CORROSION IN AFT PIT BILGE AREA ON STRINGERS & FASTENERS DOUBLER CUT OUTS FROM FRAME 63 - FRAME 64. R & R STRINGER 41RT FROM FRAME 58 - FRAME 64 IAW SRM 51-42-11, PG 7 E.