What was found
RIGHT ELEVATOR UPPER SKIN SURFACE HAS A WATER INGRESS INDICATION 39 INCHES FROM INBD END, 3 INCHES FROM TE, 3.5 INCHES DIAMETER. REPAIRED RT ELEVATOR UPPER SKIN AT LOCATION NOTED. DRILLED WITNESS HOLES & FOUND WATER. CUT OUT, SANDED AREA & REMOVED WATER. APPLIED REPAIR & RESTORED FINISH. RT ELEVATOR UPPER SKIN REPAIR AT 39 INCHES FROM INBD & 3 INCHES FROM TE.