What was found
STRINGER SPLICES HAVE CORROSION AT FRAME 27 - FRAME 28 & STRINGER 39L - STRINGER 42L. UPON FURTHER EVALUATION CORROSION WAS FOUND TO BE OUT OF LIMITS IAW SRM 51-73-11. R & R 4 EACH SPLICES AT ABOVE LOCATIONS IAW SRM 51-42-11 PARA 7.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
STRINGER SPLICES HAVE CORROSION AT FRAME 27 - FRAME 28 & STRINGER 39L - STRINGER 42L. UPON FURTHER EVALUATION CORROSION WAS FOUND TO BE OUT OF LIMITS IAW SRM 51-73-11. R & R 4 EACH SPLICES AT ABOVE LOCATIONS IAW SRM 51-42-11 PARA 7.