As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
MAIN DECK STATION 947.5 RBL 50 - 53 LAVATORY E AFTER OTBD TIE DOWN FITTING ATTACH FLOOR STRUCTURE FOUND CORROSION. CORROSION REMOVED IAW SRM 51-10-02. BLENDED OUT AREA DEPTH 0.105, ORG THK 0.180 X WIDTH 1'' X LENGTH 3'' OUT OF SRM 53-70-51 ALLOWABLE DAMAGE 1 FIG 103 LIMIT & CORRODED FLOORBEAM REPAIR IAW SRM51-70-51 REPAIR 5 FIG 206 AT RBL 8 TO RBL 60.