What was found
FUSELAGE FRAME STATION 500A HAS CRACK INDICATION BETWEEN STRINGERS 8L & 9L AT INBD HOLE ATTACHING BRACKET. REPAIRED CRACKED AREA AT FRAME STATION 500A BETWEEN STRINGER 8L - 9L INBD HOLE ATTACHING BRACKET IAW EA 5310-04716 REV F.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
FUSELAGE FRAME STATION 500A HAS CRACK INDICATION BETWEEN STRINGERS 8L & 9L AT INBD HOLE ATTACHING BRACKET. REPAIRED CRACKED AREA AT FRAME STATION 500A BETWEEN STRINGER 8L - 9L INBD HOLE ATTACHING BRACKET IAW EA 5310-04716 REV F.