What was found
FUSELAGE FRAME AT FS 500A HAS SMALL VISUAL CRACK INDICATION FROM ATTACH BRACKET INBD FASTENER HOLE BETWEEN STRINGER 8R & 9R, 51-00 2. REPAIRED CRACKED AREA AT FRAME STATION 500A BETWEEN STRINGER 8R & 9R IAW EA 5310-04716 REV F.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
FUSELAGE FRAME AT FS 500A HAS SMALL VISUAL CRACK INDICATION FROM ATTACH BRACKET INBD FASTENER HOLE BETWEEN STRINGER 8R & 9R, 51-00 2. REPAIRED CRACKED AREA AT FRAME STATION 500A BETWEEN STRINGER 8R & 9R IAW EA 5310-04716 REV F.