What was found
CABIN INTERIOR FRAME AT STA 1120 HAS CRACK AT ATTACH FASTENER BETWEEN STRINGER 8R & 9R. INSPECTION REPAIR IAW SRM 53-00-07, REPAIR 1, PAGE 207, 16,571 CYCLES NOW. INSPECTION THRESHOLD ZONE 3, 12,000 FLT CYCLES FROM REPAIR INSTALL, OR 50,000 AIRFRAME FLT CYCLES, WHICHEVER COMES FIRST REPEAT INSPECTION METHOD DVI, INTERVAL 12,000 FLT CYCLES.