What was found
R1 EXIT SIGN & EMERGENCY LIGHT INOPERATIVE. REPLACED FUSE IN POWER SUPPLY M1674 IAW AMM 33-51-06. PERFORMED OPERATIONS CHECK OF R1 EXIT SIGN & EMERGENCY LIGHT. OPERATIONS CHECKED NORMAL IAW 33-51-06.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
R1 EXIT SIGN & EMERGENCY LIGHT INOPERATIVE. REPLACED FUSE IN POWER SUPPLY M1674 IAW AMM 33-51-06. PERFORMED OPERATIONS CHECK OF R1 EXIT SIGN & EMERGENCY LIGHT. OPERATIONS CHECKED NORMAL IAW 33-51-06.