What was found
FUSE SKIN DENT AT STATION 275 JUST BELOW STRINGER 19R. CUT OUT DAMAGE & SKIN THICKNESS IS .045 INCH AREA. INSTALLED REPAIR DOUBLER THICKNESS IS .050 IAW SRM 53-00-01 REPAIR 3 FG 201.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
FUSE SKIN DENT AT STATION 275 JUST BELOW STRINGER 19R. CUT OUT DAMAGE & SKIN THICKNESS IS .045 INCH AREA. INSTALLED REPAIR DOUBLER THICKNESS IS .050 IAW SRM 53-00-01 REPAIR 3 FG 201.