What was found
BLIND FASTENER ON UPPER EXTERNAL FUSELAGE AT BS 572, STRINGER 6L. R & R BLIND FASTENERS WITH SOLID FASTENER ON UPPER FUSELAGE AT BS 572 STRINGER 6L IAW SRM 53-00-01. REPAIRED DAMAGE STRINGER COMMON TO THE BLIND FASTENER HOLE AT BS 572 STRINGER 6L IAW SRM 53-00-03 REPAIR 1 FIG 201. STRINGER REPAIR AT BS 572 STRINGER 6L IS A CAT A REPAIR ZONE 1 WITH REPEAT INSPECTION. ACCOMPLISHED HFEC OF FASTENER HOLES & 10 EA HOLES COMMON TO REPAIR IAW NDTM 51-00-16, NO DEFECTS NOTED.