What was found
SEVERAL AREAS OF CORROSION WERE FOUND ON THE FLOORBEAM UPPER SURFACE OF MAIN DECK SMAX=0.5"X0.2" STATION 986.5 LBL 30 - LB 45. CUT & REMOVED THE DAMAGED FLANGE BETWEEN LBL 40 & RBL 40, LBL 40 & LBL 60 & RBL 40 & RBL 60. LOCATED & DRILLED UP T CHORD, SHEAR TIES & INTERCOSTALS. INSTALLED THE REPAIR PARTS IAW SRM 53-70-51 R4 REV 50-CONT & INSTALLED THE ADJACENT STRUCTURE. APPLIED CIC TO THE REPAIRED AREA.