TWO CORROSIONS WERE FOUND ON THE FLOOR SUPPORT OF MAIN DECK. SMAX=0.2"*0.2" STATION 991.5 RBL 36 RBL43. REMOVED THE FLOOR SUPPORT IAW SRM 51-40-02 GEN REV 50. OK TO INSTALL. INSTALLED THE NEW FLOOR SUPPORT IAW SRM 51-40-02 REV 58.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
TWO CORROSIONS WERE FOUND ON THE FLOOR SUPPORT OF MAIN DECK. SMAX=0.2"*0.2" STATION 991.5 RBL 36 RBL43. REMOVED THE FLOOR SUPPORT IAW SRM 51-40-02 GEN REV 50. OK TO INSTALL. INSTALLED THE NEW FLOOR SUPPORT IAW SRM 51-40-02 REV 58.