What was found
LT FWD PIT DOOR LATCH FITTINGS NR 2 FWD & AFT LUG & NR 3 FWD LUG WERE GOUGED ON THE RADIUS EDGE IN ZONE A. LUGS REWORKED IAW SRM 53-26-00 PAR 4 A. REMAINING MATERIAL THICKNESS IS FTG NR 2 FWD LUG 0.471 INCHES, AFT LUG 0.483 INCHES & FTG NT 3 FWD LUG 0.478 INCHES, MIN ALLOWABLE IS 0.430 INCHES. WORK ACP ON NR 45604 REQUIRES REINSP IAW SRI53-26-00-1-001-00 PARA 3 A. TBL 102.1ST INSP 4200C FROM REP EMBODIMENT & EVERY 4200C THEREAFTER.