What was found
AFT GALLEY FLOOR SUPPORT CORRODED AT STATION 1681 FWD OF RT OTBD GALLEY MOUNT. NEW DOUBLER INSTALLED IAW ECRA 5 330-04259 REV. PERFORMED HFEC IAW NDT51-00-19. ALODINED, PRIMED & TOP COATED IAW SRM 51-20-01.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
AFT GALLEY FLOOR SUPPORT CORRODED AT STATION 1681 FWD OF RT OTBD GALLEY MOUNT. NEW DOUBLER INSTALLED IAW ECRA 5 330-04259 REV. PERFORMED HFEC IAW NDT51-00-19. ALODINED, PRIMED & TOP COATED IAW SRM 51-20-01.