What was found
FUSELAGE EXTERIOR SKIN DENT AT STATION 2100 RT STRINGER 29R - 30R. DENT OUT OF LIMITS IAW 53-00-01. THIS EXT DOUBLER REPAIR 7 IS A CAT B REPAIR IN ZONE B. SUBSEQUENT INSPECTIONS ARE NECESSARY FOR REPAIR 7 IAW PARA 6 REPAIR 7 PAGE 216, TABLE 204. INTERNAL HFEC RECOMMENDED IAW NDT. IAW NDT PART 6, 53-00-06 & DETAILED VISUAL INSPECTION PARTIAL. DOUBLER REPAIR AT STATION 2087 TO 2108. STRINGER 29R - 30R REQ RE INSPECTION EVERY 16K CYCLE THRESHOLD AT TIME OF REPAIR. CURRENT PTC=13244. INITIAL CRITICAL ROWS OF FASTENERS ARE ZERO TIMED. MF4149 ADDED TO MONITOR. HOLES 0 TIMED THRESHOLD IS 30000 CYC FROM TIME REPAIR WAS INSTALLED WITH REPEAT INSP EVERY 16000 CYC THEREAFTER. INSPECTION IAW SRM 53-00-01 RPR 7 TABLE 204. THIS IS A PERM REPAIR PROVIDED REPEAT INSPECTION ON MF4149 ARE ACCOMPLISHED. MOVED CF548 TO CF9 STATUS & REMOVED HARD TIME LIMITS.