What was found
CABIN FLOORBEAM CORRODED STATION 328 AT LBL 11.50. REMOVED DAMAGED SECTION OF FLOOR BEAM FABRICATED & INSTALLED REPAIR PARTS IAW SRM 53-00-51 REPAIR 1.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
CABIN FLOORBEAM CORRODED STATION 328 AT LBL 11.50. REMOVED DAMAGED SECTION OF FLOOR BEAM FABRICATED & INSTALLED REPAIR PARTS IAW SRM 53-00-51 REPAIR 1.