What was found
PERFORMED MID & HIGH FREQ EDC FRAME AT STRINGER 8L STATION 500A LT. FOUND INBD FASTENERS CRACKED RADIUS & OTBD FASTENER GOOD. FRAME AT STATION 500A LT BETWEEN STRINGER 8L & 9L HAS BEEN REPAIRED IAW EA 5310-04716 REV G OP 2 FIG 3.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
PERFORMED MID & HIGH FREQ EDC FRAME AT STRINGER 8L STATION 500A LT. FOUND INBD FASTENERS CRACKED RADIUS & OTBD FASTENER GOOD. FRAME AT STATION 500A LT BETWEEN STRINGER 8L & 9L HAS BEEN REPAIRED IAW EA 5310-04716 REV G OP 2 FIG 3.