What was found
FS 947 FLOORBEAM CORRODED UNDERNEATH RT OTBD LAVATORY MOUNT STATION 947. FLOORBEAM AT RBL 50 HAS BEEN REPAIRED IAW SRM 53-70-51 REPAIR 5.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
FS 947 FLOORBEAM CORRODED UNDERNEATH RT OTBD LAVATORY MOUNT STATION 947. FLOORBEAM AT RBL 50 HAS BEEN REPAIRED IAW SRM 53-70-51 REPAIR 5.