What was found
SUPPORT TASK RT FRAME AT STATION 500C BETWEEN STRINGER 8 - 9 SUPPORT BRACKET ATTACHMENT AREA FOUND INBD RIVET HOLE CRACKED AT FRAME LAYER APPROX 1/8 INCH LONG RUNNING INBD & APPROX 1/8 INCH LONG RUNNING DOWN. CABIN RT FRAME AT STATION 500C BETWEEN STRINGER 8 - 9 FRAME REPLACED IAW EA5310-04716 REV G FIG 3. ATTACH MX WORK SHEET FORM 44.0008 ITEM 1 TO ITEM 20 ACCOMPLISHED. HFEC NIL CRACK FOUND IAW NTM PART 6 51-00-00 PROC 23 EA5310-04716 REV G OP 02.