What was found
FOUND SEVEN WIRES CHAFED & SHORTING TO CARBON FIBER PANEL AT APO315, POS 6 D6113J, WIRES W9971-0035, 0036, 0044, 0045, 0058, 0059 & 0060. REPLACED WIRES W9971-0058 -20, -0059-20, -0060-20 IN D9602P IAW DWG A603301-005 PG 47. ROUTED & SECURED WIRES. TERMINATED WIRES -0035 & -0036 AT D263P IAW WDM 33-24-21. SECURED ALL WIRES & INSTALLED ADDITIONAL SUPPORT TO PREVENT AFFECTED BUNDLES FROM CONTACTING STRUCTURE IAW DWG A603385-011 GN 11.