What was found
LEFT WING FUEL PANEL 540MB HAS TWO EACH GOUGED FASTENER S HOLES. REAMED TWO EACH HOLES ON PANEL 540MB, COLD WORKED HOLES & REAMED. FABRICATED TWO BUSHINGS & INSTALLED ON PANEL. BRIDGE PLATE INSTALLED WET IAW SRM 57-21-11 PARA 5 B FIG 202. PANEL REQUIRES RE-INSPECTION IAW SRI57-21-11 PAGES 207 - 208. FIRST INSPECTION AFTER ACFT 1ST FLIGHT 31100 FC & SUBSEQUENT 3600 FC.