What was found
ELECTRICAL BURNING ODOR NEAR SEAT 23A SMELLED LIKE BALLAST. SMELL INTERMITTENT, PILOT PERFORMED CONDITIONAL INSPECTION IAW AMM 05-51-58-200-801C1 STEP C1, C2A & C2C, NO DISCREPANCY FOUND. DI 01035 NO OBVIOUS SMELL AT OR AROUND 23ABC WHEN DOING OPERATIONS INSPECTION WITH ENG RUNNING STEP I TO S. COMPLETED STEPS C2B, C2D & C2E. INSPECTION WITH IFE ON AFTER 2 HRS. INSPECTIONS COMPLIED WITH REQ OF AMM 05-51-58, NO DEFECTS.