What was found
AFTER STATION 1681 FRAME SECTION REMOVAL FOUND OTBD CHORD BETWEEN STRINGS 17R & 18R TO HAVE THREE EACH HOLES WITH PREVIOUS COUNTER BORES. REMOVED DAMAGED SECTION OF THE OTBD CHORD, FABRICATED REPLACEMENT CHORD & SPLICE ANGLE. INSTALLED REPLACEMENT CHORD IAW EA 130464IR & ECRA 5360-01303 AT BS 1681 BETWEEN STRINGERS 14R & 20R. MUST BE INSPECTION EVERY 24 MONTHS OR 3000 FLT CYCLES WHICHEVER COMES FIRST. ACCOMPLISHED INSPECTION IAW PART 2 OF ECRA 5360-01303. INSPECTED & COMPLIED WITH METER IAW PART 2 OF ECRA 5360-01303. NO RECORDABLE DISCREPANCIES NOTED.