6 INCH LONG CRACK AFT OF STATION 1629 AT STRINGER 14R IAW AVO ESC 140714-6671-1A COMPLIED WITH SRM 53-00-01 REPAIR 1 STEPS 1 THRU END. FINAL SIGN OFF IS PENDING ECRA FROM ENGINEERING. CONT OF AMIS ITEM 9132007. REPAIRED IAW ECRA 5331-01 921 REV A & ESC140714-6671-1A. PLACED ON CF TO ACCOMPLISH A PERMANENT REPAIR WITHIN 24 MONTHS FROM 15 JULY 2014. PLANNING TO CONTACT ENGINEERING AFTER 22 MONTHS BUT BEFORE 23 MONTHS FOR A PERMANENT REPAIR SEE FORM 44.0008 FOR WORK ACCOMPLISHED. REPAIR ACCOMPLISHED IAW ECRA 5331-01921 & SRM 53-00-01 REPAIR 1. ALL PARTIAL WORK DOCUMENTED ON 44.0008 & SENT TO ACFT RECORDS.