What was found
EXTERNAL FUSELAGE STATION 1706 RT SIDE STRINGER 14R - 15R WL 223 JUST FWD OF HORIZONTAL STABILIZER SKIN HAS TWO DEEP SCRATCHES. FIG 201 TBL V ALTERNATIVE I INTERNAL HFEC EACH 12OOOC. REPAIR IS CATEGORY B REPAIR WITH INSPECTION THRESHOLD BEGINNING 37500 PTC OR 6000C AFTER REPAIR EMBODIMENT, WHICHEVER COMES LATER, WITH REPEAT INSPECTIONS THEREAFTER. INSPECTION METHODS & FREQUENCY IDENTIFIED IN SRM 53-00-01 FIG 201 TBL V PG 209. AFTER INITIAL INSPECTION 37500PTC, REPEAT INSPECTIONS GOVERNED BY SRM 53-00-01.