What was found
AFT CARGO COMPARTMENT BILGE FLOOR PAN BEAM AT STATION 1220 CORRODED AT SEVERAL NUTPLATES MARKED APPROXIMATELY 8. R & R FLOORBEAM J CHANNEL UPPER CHORD IAW 51-40-02 & DWG 146 1060.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
AFT CARGO COMPARTMENT BILGE FLOOR PAN BEAM AT STATION 1220 CORRODED AT SEVERAL NUTPLATES MARKED APPROXIMATELY 8. R & R FLOORBEAM J CHANNEL UPPER CHORD IAW 51-40-02 & DWG 146 1060.