What was found
CABIN FLOOR STRUCTURE BS 848 RBL 54.75 CORRODED. REMOVED DAMAGE, FABRICATED & INSTALLED NEW FLOORBEAM BS 838 TO 883 RBL 54.75 IAW SRM 53-00-51.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
CABIN FLOOR STRUCTURE BS 848 RBL 54.75 CORRODED. REMOVED DAMAGE, FABRICATED & INSTALLED NEW FLOORBEAM BS 838 TO 883 RBL 54.75 IAW SRM 53-00-51.