What was found
MAIN DECK FLOOR PANEL SUPPORT FROM STATION 1830 - 1890 LBL CORROSION. REPAIRED IAW SRM 53-00-52 REPAIR 5 & SRM 51-40-02. NDT INSP IAW PT6 51-00-0 0 PROC 23. NO CRACK FOUND.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
MAIN DECK FLOOR PANEL SUPPORT FROM STATION 1830 - 1890 LBL CORROSION. REPAIRED IAW SRM 53-00-52 REPAIR 5 & SRM 51-40-02. NDT INSP IAW PT6 51-00-0 0 PROC 23. NO CRACK FOUND.