What was found
OP 2 CABIN FRAME INSPECTION. FOUND CRACK INDICATION ON INBD RIVET STATION 500AL. REPAIRED FRAME AT STATION 500AL BETWEEN STRINGER 8L & 9L. SEE ALL TASKS & WIPS FOR PARTIAL WORK ACCOMPLISHED IAW EA 5310-04716 REV H OP 02.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
OP 2 CABIN FRAME INSPECTION. FOUND CRACK INDICATION ON INBD RIVET STATION 500AL. REPAIRED FRAME AT STATION 500AL BETWEEN STRINGER 8L & 9L. SEE ALL TASKS & WIPS FOR PARTIAL WORK ACCOMPLISHED IAW EA 5310-04716 REV H OP 02.