What was found
NUMBER 2 ENG SN V12 083 HAD TWO EACH COMPRESSOR STALLS AFTER TAKEOFF. FOLLOWED FM PROCEDURE, THROTTLE BACK TO IDLE, CURRENTLY ENG PARAMETERS NORMAL. RETURNING BACK TO FIELD. CFDS SHOWS ENG 2 STALL 2 TIMES IN CRUISE, WITH VSV BLD VLV LP C2 ALONG WITH ENG 2 FADEC B FAULT. ACCOMPLISHED TROUBLESHOOTING IAW TSM 71-00-00-810-809-A 13. REPLACED 7TH STAGE BLEED VALVE & LUBED VSV RING IAW SEQ 0992034, 0992031, 0992026 & ACP POWER ASSURANCE RUN.