As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
RE INSPECTION IAW SRM 53-00-01 TABLE V USING LOW FREQ METHOD IAW NDT PART 6 51-00-06. RAMP REPORTED A DENT AT STATION 1680 APPROX 3 FEET BEHIND DOOR 4L. ALL RE INSPECTION COVERED ON CF9067. VERIFIED DENT IS FREE OF CRACKS USING HFEC. DENT LOCATED AT STATION 1705 BETWEEN STRINGER 18L & 19L.