What was found
REF A CHECK J C 6-2006-A ITEM 2C 3 GUARDED EMER LIGHT SWITCH ON P22 AFT ATTENDANTS PANEL WHEN PUSHED TO ON POSITION DOES NOT ILLUMINATE EMER LIGHTS. FOUND WIRE W1224-087-22 INSTALLED IN WRONG LOCATION OF CONNECTOR D4290P IAW WDM 33-27-11 PG 2A SHEET 4. WIRE SHOULD BE TERMINATED AT PIN 49, BUT IS CURRENTLY IN POSITION 39. RELOCATE WIRE TO CORRECT POSITION IAW WDM. REMOVED WIRE W1224-087-22 FROM POS 39 & REINSTALLED INTO POSITION 49 OF CONNECTOR D4290 P IAW WDM 33-27-11. OPERATIONS NORMAL IAW MM 33-51-00.