What was found
LEADING EDGE ASYMMETRIC EICAS MSG HAPPENED INTERMITTENTLY ABOVE 14K WITH SPEED ABOVE 280 KNTS. MSG ACCOMPANIED BY FLAP CONTROL SYNOPTIC WITH AMBER LE INDICATION 27-81021. TROUBLE SHOT IAW FIM 32-09-03-101. PERFORMED PSEU BITE CHECK FOUND STRINGER 276 NR 1 SLAT OTBD SENSOR AT FAULT. R & R S276 IAW AMM 27-88-01-9 02-001. OPERATIONS CHECKED IAW AMM 27-88-00-715-098, OPERATIONS CHECKED GOOD NO FURTHER FAULTS NOTED AT THIS TIME. OK TO CONTINUE.