What was found
FORWARD CARGO INNER AFT BILGE AREA HAS CORROSION ON STRINGER 24L AROUND RIVETS HOLES AS MARKED 4 TO 8 INCHES FWD OF FRAME 34. R & R WITH NEW FACTORY STRINGER 24 LT FROM FRAME 30 TO 34 IAW SRM 51-42-11.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
FORWARD CARGO INNER AFT BILGE AREA HAS CORROSION ON STRINGER 24L AROUND RIVETS HOLES AS MARKED 4 TO 8 INCHES FWD OF FRAME 34. R & R WITH NEW FACTORY STRINGER 24 LT FROM FRAME 30 TO 34 IAW SRM 51-42-11.