As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
STRUCTURE CORRODED FROM STATION 294.5 TO 350 ALL ALONG STRINGER 23L APPROX INSIDE E & E BAY. REPAIRED STRUCTURE IAW ECRA 5310-06308, SEE WIP ENTRIES FOR ALL WORK PERFORMED. INITIATED A DIP TO ACCOMPLISH A PERMANENT REPAIR ON OR BEFORE 11/15/2016. PLANNING TO CONTACT ENGINEERING AFTER 09/15/2016 BUT BEFORE 10/15/2016 FOR THE PERMANENT REPAIR.