What was found
FORWARD CARGO INNER AFT BILGE AREA HAS CORROSION ON STRINGER AROUND RIVET HOLES AS MARKED 1 TO 6 INCHES FWD OF FRAME 34. R & R STRINGER 44 FROM FRAME 30 & 31 TO END FITTING AT FRAME 35 IAW SRM 5 1-42-11.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
FORWARD CARGO INNER AFT BILGE AREA HAS CORROSION ON STRINGER AROUND RIVET HOLES AS MARKED 1 TO 6 INCHES FWD OF FRAME 34. R & R STRINGER 44 FROM FRAME 30 & 31 TO END FITTING AT FRAME 35 IAW SRM 5 1-42-11.