What was found
MAJOR REPAIR & SDR. LEFT ELEVATOR UPPER SKIN PANEL HAS TRAPPED WATER INDICATION AT 5 LOCATIONS AS FOLLOWS. 1) 16 INCHES FROM INBD, 17 INCHES FROM TE & 1.5 INCHES IN DIAMETER. 2) 73 INCHES FROM INBD, 21 INCHES FROM TE & 3.5 INCHES X 8 INCHES UNDER LIGHTNING ARRESTER. 3) 98 INCHES FROM INBD, 20 INCHES FROM TE & 1 INCH IN DIAMETER. 4) 102 INCHES FROM INBD, 16 INCHES FROM TE & 1 INCH IN DIAMETER. 5) 149 INCHES FROM INBD, 14 INCHES FROM TE & 1.5 INCHES IN DIAMETER. APPLIED REPAIRS & RESTORED FINISH IAW SRM 55-21-11 PARA 5D. REPAIR REQUIRES RE-INSPECTION IAW SRI 55-21-11-2 -002-00 TABLE 203.