What was found
AFT PIT FRAME HAS EXFOLIATION CORROSION STATION 1480, STRINGER 25 - 26R. REMOVED DAMAGED SECTION OF RIB STATION 1480, STRINGER 26 - 25R. INSTALLED NEW SECTION IAW SRM 530-00 -07 REPAIR 5. SPLICE PLATES & J ANGLE REPAIR.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
AFT PIT FRAME HAS EXFOLIATION CORROSION STATION 1480, STRINGER 25 - 26R. REMOVED DAMAGED SECTION OF RIB STATION 1480, STRINGER 26 - 25R. INSTALLED NEW SECTION IAW SRM 530-00 -07 REPAIR 5. SPLICE PLATES & J ANGLE REPAIR.