What was found
LEFT ELEV UPPER SKIN HAS A WATER INGRESS INDICATIONS AT THE FOLLOWING LOCATIONS, 27.5 INCHES FROM INBD END 15 INCHES FROM TE & 2 INCHES IN DIAMETER. NEXT 17 INCHES FROM INBD END 29 INCHES FROM TE & 2 INCHES IN DIAMETER. NEXT 41 INCHES & 43 INCHES FROM INBD END 16 INCHES & 18 INCHES FROM TE. NEXT 19.5 INCHES FROM INBD END 10 INCHES FROM TE & 2 INCHES IN DIAMETER. NEXT 125 INCHES FROM INBD END 20. RT ELEV UPPER SKIN PANEL HAS TRAPPED WATER INDICATION AT 3 LOCATIONS, 1- 175 INCHES FROM INBD END 4 INCHES FROM TE WITH 3 INCHES IN DIAMETER. 2 - 156 INCHES FROM INBD END 17 INCHES FROM TE WITH 2 INCHES IN DIAMETER. 3- 166 INCHES FROM INBD END 5 INCHES FROM TE WITH 2 INCHES DIAMETER, ALL IN ZONE 3. FROM TE 3 INCHES IN DIAMETER . CUT OUT OUT TRAPPED WATER INDICATION IN ALL LOCATIONS APPLIED REPAIRS & RESTORED FINISH IAWSRM55-21-11 PARA 5E.