As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
RIGHT ELEVATOR UPPER SURFACE HAS A TRAPPED WATER INDICATION. 113 INCHES FROM INBD, 12 INCHES FROM TE & 6 INCHES IN DIAMETER & THE LOWER SURFACE 80 INCHES FROM INBD, 5 INCHES FROM TE & 2 INCHES IN DIAMETER. CUT OUT TRAPPED WATER & APPLIED REPAIR CONFIG 1 & RESTORED FINISH IAW SRM 55-21-11 PARA 5E. SRI 55-21-11-2-002-00 REQUIRES 1ST INSP AFTER COMPONENT DELIVERY AT 48000C OR 60000T.