What was found
R2 DOOR SILL HAS LIGHT CORROSION ON FRAME 66R - 68 FWD EDGE. REMOVED CORROSION ON DOOR SILL & FOUND OUT OF LIMITS. FABRICATED REPAIR 2 REPAIR ANGLES & INSTALLED IAW SRM 53-41-14 PARA 5A REPAIR PRINCIPLE 9.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
R2 DOOR SILL HAS LIGHT CORROSION ON FRAME 66R - 68 FWD EDGE. REMOVED CORROSION ON DOOR SILL & FOUND OUT OF LIMITS. FABRICATED REPAIR 2 REPAIR ANGLES & INSTALLED IAW SRM 53-41-14 PARA 5A REPAIR PRINCIPLE 9.