What was found
SUPPORT TASK ELONGATED HOLE AT STRINGER 3 RT AT STATION 727D. THIS NON-ROUTINE FOR SDR TRACKING PURPOSES ONLY. ALL WORK ACCOMPLISHED REACHED. INITIATED DIP CONTROL 031722. ACCOMPLISHED ON NON-ROUTINE 6415610. STRINGER SPLICE REPAIR ACCOMPLISHED AT STRINGER 3R, STATION 727+0 TO 727E+12 IAW SRM 53-00-03 REPAIR 3 CATEGORY B. REPAIR THRESHOLD FOR START OF SUPPLEMENTAL INSPECTION IS 61727 CYCLES & EVERY 2350 FLIGHT CYCLES AFTER THRESHOLD. ACCOMPLISH INSPECTION AT THRESHOLD OF 50,000 FLIGHT CYCLES AFTER THE REPAIR & INTERVALS OF EVERY 2350 FLIGHT CYCLES THERE AFTER IAW SRM 53-00-03 REPAIR 3 PARA 5 A 2.