What was found
EXPERIENCED COMPLETE LOSS OF NR 1 HYD SYS PRIOR TO DESCENT. FOUND SYS 1 RETURN LINE WITH A PUNCTURE, IPC REFERENCE 29-11-60-001J, ITEM 270. R & R NR 1 HYD SYS RETURN LINE. SYS OPERATIONS & LEAK CHECKED OK.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
EXPERIENCED COMPLETE LOSS OF NR 1 HYD SYS PRIOR TO DESCENT. FOUND SYS 1 RETURN LINE WITH A PUNCTURE, IPC REFERENCE 29-11-60-001J, ITEM 270. R & R NR 1 HYD SYS RETURN LINE. SYS OPERATIONS & LEAK CHECKED OK.