What was found
TWO HOLES JUST ABOVE STRINGER 22 LT IN THE STATION 540 BULKHEAD CHORD SHOW CRACK INDICATION. CRACK INDICATION ARE IN THE CHORD ONLY. THE TWO HOLES ARE COMMON TO THE DRAG LINK ASSEMBLY. INSTALLED INTERIM REPAIR DOUBLER & FREEZE PLUG IAW ECRA 5310-064 76. ACCOMPLISH INSPECTION REQUIREMENTS ON OR BEFORE 36000 TOTAL FLIGHT CYCLES. PLANNING TO CONTACT ENGINEERING AFTER 30000 CYCLES BUT BEFORE 31000 CYCLES FOR INSPECTION REQUIREMENTS IAW ECRA 5310-06476.