As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
HFEC CRACK INDICATION AT FASTENER HOLES COMMON TO THE SPLICE STRAP, ON SEAT TRACK OTBD FLANGES FWD OF FLOORBEAM STATION 727B AT RBL 45.5, AS INDICATED BY EA 5320-02076 REV F STEP 3.6. REPAIRED SEAT TRACK IAW ECRA 5320-02470. SEE ENTRIES BELOW FOR ALL WORK PERFORMED.