What was found
CRACK INDICATION FOUND IAW EA5310-04716 REV L AT STATION 440R BETWEEN STRINGER 8 & 9. REPAIRED IAW EA5310-04716 REV L. ALL PARTIAL WORK HAS BEEN ACCOMPLISHED .
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
CRACK INDICATION FOUND IAW EA5310-04716 REV L AT STATION 440R BETWEEN STRINGER 8 & 9. REPAIRED IAW EA5310-04716 REV L. ALL PARTIAL WORK HAS BEEN ACCOMPLISHED .