What was found
TENSION TIE RT STATION 1140 FAILSAFE CHORD CRACK FOUND. TENSION TIE RT STATION 1140 FAILSAFE CHORD REPAIRED IAW EA 5310-05635 OP19 STEP 10 & SRM 53-40-07 REPAIR 10 FIG 201 REV 92.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
TENSION TIE RT STATION 1140 FAILSAFE CHORD CRACK FOUND. TENSION TIE RT STATION 1140 FAILSAFE CHORD REPAIRED IAW EA 5310-05635 OP19 STEP 10 & SRM 53-40-07 REPAIR 10 FIG 201 REV 92.