What was found
DURING ACCOMPLISHMENT OF EA 5300-01721 REV C OP 04, WEAR WAS FOUND ON THE PN 65B02706-80 SKIN PANEL AT APPROX STATION 2580, STRINGER 3R. THE BLEND OUT EXCEEDED ALLOWABLE LIMITS IN SRM 53-00-01. DAMAGE WAS CUT OUT & A REPAIR DOUBLER INSTALLED IAW ECRA 5330-04937. THE FUSE SKIN REPAIR INSTALLED IAW ECRA 5330-04937 AT STATION 2580, STRINGER 3R HAS RECEIVED 1ST & 2ND STAGE APPROVAL. PERMANENT REPAIR ACCOMPLISHED DURING HMV BY INSTALLING RUB STRIPS IAW EA 5331-01768. OK TO THIS CF IAW ECRA 5330-04937 REV A.