What was found
FUSELAGE SKIN FRAME 35 & CM10 THE LT AFT LOWER HOLE NR 2 HAS CRACK INDICATION 5:00 POSITION. REPAIRED NR 2 HOLE & INSTALLED FASTENER LT FRAME 35 IAW ECRA 53-30-04940 & THIS IS TEMP REPAIR. REPAIR OF CRACKED & ELONGATED FASTENER HOLE FRAME 35 BELOW STRINGER 30 LT HAS BEEN APPROVED AS INTERIM FOR 6 MONTHS IAW RDAS 8 0006388-003-2014 ISSUED NOV 7 2014. A NEW RDAS THAT PROVIDES INSPECTION THRESHOLD MUST BE REC PRIOR TO MAY 7 2014 IF NEW RDAS IS NOT RECEIVED PRIOR TO MAY 7 2015 THE ACFT IS NOT AIRWORTHY.